C2 Range Recessed Air Curtains

C2 Range Recessed Air Curtains from Thermoscreens are compact in design for mounting heights up to 2.75m. Ideal for retails outlets such as Boutiques, Restaurants, Bars etc.

If the door way is exposed to prevailing winds you should consider the Thermoscreens standard over the door air curtain for light commercial use (T Range).

Recommended Height: 2.75m max recommended height
Widths available:            1m, 1.5m and 2m

PRODUCT FEATURES

  • 9 options available in Electric, LPHW or Ambient
  • Electric & LPHW models use ecopower controller
  • Ambient models use switch controller
  • Integrated/remote Thermostat
  • Energy Efficient
  • BMS compatible
  • 3 – way Valve (water units)
  • Fitted with Tangential Fans
  • Optional filters available for LPHW or Ambient models only
  • Instant Heat
  • Powerful Heat output
  • Maximum mounting height 2.75m
  • RAL 9010

TECHNICAL SPECIFICATIONS

Models  Dimensions  Grille Size Supply Heat  Loading  Max.  Max. Air  Weight  **dB(A) 
(mm)  inc. Flange (50Hz) Output  (A) *per  Velocity  Volume  (kg)  @3m 
(L x D x H)  (mm)   (kW)  phase  (m/s)  (m3/h)    High Med Low
Ambient
C2-1000AR 1161 x 301 x 206 1209 x 353 230V~1P &N 0.7 9.0 1250 19 52 50 48
C2-1500AR 1561 x 301 x 206 1609 x 353 230V~1P&N 0.9 9.0 1800 25 52 50 48
C2-2000AR 2072 x 301 x 206 2120 x 353 230V~1P&N 1.1 9.0 2500 35 53 51 49
Electric
C2-1000ER 1161 x 301 x 206 1209 x 353 400V~3P&N 4.5/9 *13.7 9.0 1250 20 52 50 48
C2-1500ER 1561 x 301 x 206 1609 x 353 400V~3P&N 6/12 *18.3 9.0 1800 27 52 50 48
C2-2000ER 2072 x 301 x 206 2120 x 353 400V~3P&N 9/18 *27.2 9.0 2500 37 53 51 49
LPHW
C2-1000WR 1161 x 301 x 206 1209 x 353 230V~1P&N 6 0.7 8.5 1250 22 52 50 48
C2-1500WR 1561 x 301 x 206 1609 x 353 230V~1P&N 9 0.9 8.5 1800 30 52 50 48
C2-2000WR 2072 x 301 x 206 2120 x 353 230V~1P&N 12 1.1 8.5 2500 41 53 51 49

**Sound pressure levels (dBA) at 3m, as given above, are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several dB higher if the mounting height is reduced, if the room is more “live” (i.e. hard surfaces, no furnishings or absorbent materials), if the room is smaller than 8 ac/h equivalent or a combination of these factors. Noise levels will also increase if more than one air curtain is installed at the same doorway (e.g. + 3dBA for 2 equal point sources: direct field).

Models

C1000E9R-9KW3P
C Range recessed Electric 9kW 3Ph 1m
C1500E12R-12KW3P
C Range recessed Electric 12kW 3Ph 1.5m
C2000E18R-18KW3P
C Range recessed Electric 18kW 3Ph 2m