Key Features
  • Future Forward - offering smart energy management and an emergency power function
  • Energy Independence - offers seamless transition to backup and PID Recovery modes
  • User Friendly - lightweight and easy to install
  • Smart Management - 24/7 live monitoring with remote firmware updates
  • Choose from 1-Phase Hybrid or 3-Phase Hybrid
  • 1-Phase Hybrid includes a choice of 5 sizes, 3-6kW
  • 3-Phase String includes a choice of 4 sizes, 5-10kW
Type Designation SH4.0RS SH5.0RS   SH10RT
Input (DC)        
Recommended max. PV input power 11kWp 12kWp Recommended max. PV input power 15kWp
Max. PV input voltage 600V 600V Max. PV input voltage 1000V
Min. PV input voltage / Start-up input voltage 40V / 50 V 40V / 50 V Min. PV input voltage / Start-up input voltage 200V / 250V
Rated input voltage 360V 360V Rated input voltage 600V
MPP voltage range 40V -560V 40V -560V MPP voltage range 200V – 950V
No. of independent MPP inputs 2 2 No. of independent MPP inputs 2
No. of PV strings per MPPT 1 1 No. of PV strings per MPPT 1 / 2
Max. PV input current 32A (16A / 16A) 32A (16A / 16A) Max. PV input current 37.5A (12.5A / 25A)
Max. DC short-circuit current 40A (20A / 20 A) 40A (20A / 20 A) Max. DC short-circuit current 48A (16A / 32A)
Max. current for DC connector 20A 20A Max. current for DC connector 30A
Battery data     Battery data  
Battery type Li-ion battery Li-ion battery Battery type Li-ion battery
Battery voltage 80 V – 460 V 80 V – 460 V Battery voltage 80 V – 460 V
Max charge / discharge current 30 A / 30 A 30 A / 30 A Max charge / discharge current 30 A / 30 A
Max charge / discharge power 6600 W / 6600W 6600 W / 6600W Max charge / discharge power 10600W / 10600W
Output (AC)     Output (AC)  
Rated AC output power 11000 VA 12000 VA Max. AC input power to battery 20600 W
Max. AC output power 4000 W 5000 W Max. AC power from grid 20600 W
Rated AC output apparent power 4000 VA 5000 VA Rated AC output power 10000 W
Max. AC output current 18.2 A 22.8 A Rated AC output apparent power 10000 VA
Rated AC voltage 220 V / 230 V / 240 V 220 V / 230 V / 240 V Max. AC output current 15.2 A
AC voltage range 154 V – 276 V 154 V – 276 V Rated AC voltage 3 / N / PE, 220 / 380 V; 230 / 400 V; 240 / 415 V
Rated grid frequency 50 Hz / 60 Hz 50 Hz / 60 Hz AC voltage range 270 – 480 V
Grid frequency range 45 Hz – 55 Hz / 55 Hz – 65 Hz 45 Hz – 55 Hz / 55 Hz – 65 Hz Rated grid frequency 50 Hz
Harmonic (THD) <3 % ( of rated power ) <3 % ( of rated power ) Grid frequency range 45 – 55 Hz
Power factor at Rated power / Adjustable power factor >0.99 at default value at rated power >0.99 at default value at rated power Harmonic (THD) <3% (of rated power)
Feed-in phases / Connection phases 1 / 1 1 / 1 DC Current Injection <0.5% In
Efficiency     Power factor at Rated power / Adjustable power factor >0.99 / 0.8 leading to 0.8 lagging
Max. efficiency 97.60% 97.70% Feed-in phases / Connection phases 3 / 3
European efficiency 97.20% 97.30% Efficiency  
Backup data (on grid mode)     Max. efficiency 98.40%
Rated output power for backup load 6000W 6000W European efficiency 97.90%
Rated output current for backup load 27.3 A 27.3 A Backup Data  
Backup data (off-grid mode)     Rated voltage 3/N/PE, 220 Vac/230 Vac/240 Vac
Rated voltage 220 V / 230 V / 240 V ( ± 2 % ) 220 V / 230 V / 240 V ( ± 2 % ) Frequency range 50 Hz
Frequency range 50 Hz / 60 Hz ( ± 0.2 % ) 50 Hz / 60 Hz ( ± 0.2 % ) Total hamonic factor output voltage (Linear load) 2%
Output voltage harmonic (THD) <2% <2% Switch time to emergency mode <20 ms
Switch time to emergency mode <10ms <10ms Rated output power 10000W / 10000VA
Rated output power 4000 W / 4000 VA 5000W / 5000VA Peak output power *** 12000W / 12000VA, 5min
Peak output power 8400VA, 10s 8400VA, 10s Peak output power on single phase **** 3400 VA (≥12.8kWh)
      Rated output current for backup load during on grid mode 3 x 18.5A
Downloads Inst Manual   Inst Manual
  Data Sheet   Data Sheet
  EN Cert   EN Cert