Residential Hybrid Inverters

Residential Hybrid Inverters

Next Day Delivery Across Ireland

Residential Hybrid Inverters

Grid failure? Not a problem. In case of a blackout our hybrid inverters will automatically switch into backup mode. Consult your installer regarding emergency power installation.
  • Future Forward - offering smart energy management and an emergency power function
  • Energy Independence - seamless transition to backup power
  • User Friendly - lightweight and easy to install
  • Smart Management - 24/7 live monitoring with remote firmware updates from iSolarCloud App
  • Choose from 1-Phase Hybrid or 3-Phase Hybrid
  • 1-Phase Hybrid includes a choice of 5 sizes, 3-6kW*
  • 3-Phase String includes a choice of 4 sizes, 5-10kW*
  • *Stock item info shown below
SH4.0RS SH5.0RS SH10RT
Input (DC)
Recommended max. PV input power 6kWp 7.5kWp 15kWp
Max. PV input voltage 600V 600V 1000V
Min. PV input voltage / Start-up input voltage 40V / 50V 40V / 50V 200V / 250V
Rated input voltage 360V 360V 600V
MPP voltage range 40V – 560V 40V – 560V 200V – 950V
No. of independent MPP inputs 2 2 2
No. of PV strings per MPPT 1 1 1 / 2
Max. PV input current 32A (16A / 16A) 32A (16A / 16A) 37.5A (12.5A / 25A)
Max. DC short-circuit current 40A (20A / 20A) 40A (20A / 20A) 48A (16A / 32A)
Max. current for DC connector 20A 20A 30A
Battery data
Battery type Li-ion battery Li-ion battery Li-ion battery
Battery voltage 80V – 460V 80V – 460V 80V – 460V
Max charge / discharge current 30A / 30A 30A / 30A 30A / 30A
Max charge / discharge power 6600W / 6600W 6600W / 6600W 10600W / 10600W
Output (AC)
Max. AC power from grid 11000VA 12000VA 20600W
Rated AC output power 4000W 5000W 1000W
Max. AC output apparent power 4000VA 5000VA 10000VA
Max. AC output current 18.2A 22.8A 15.2A
Rated AC voltage 220V / 230V / 240V 220V / 230V / 240V 3 / N / PE, 220 / 380V; 230 / 400V; 240 / 415V
AC voltage range 154V – 276V 154V – 276V 270V – 480V
Rated grid frequency 50Hz / 60Hz 50Hz / 60Hz 50Hz
Grid frequency range 45Hz – 55Hz / 55Hz – 65Hz 45Hz – 55Hz / 55Hz – 65Hz 45 – 55Hz
Harmonic (THD) <3 % @ rated power <3 % @ rated power <3% @ rated power
Power factor at Rated power / Adjustable power factor >0.99 at default value at rated power >0.99 at default value at rated power > 0.99 / 0.8 leading to 0.8 lagging
Feed-in phases / Connection phases 1 / 1 1 / 1 3 / 3
Efficiency
Max. efficiency 97.60% 97.70% 98.40%
European efficiency 97.20% 97.30% 97.90%
Backup data (on grid mode)
Rated output power  for backup load 6000W 6000W N/A
Rated output current for backup load 27.3A 27.3A N/A
Backup data (off-grid mode)
Rated voltage 220V / 230V / 240V  ( ± 2 % ) 220V / 230V / 240V  ( ± 2 % ) 3/N/PE, 220Vac/230Vac/240Vac
Frequency range 50Hz / 60Hz ( ± 0.2 % ) 50Hz / 60Hz ( ± 0.2 % ) 50Hz
Output voltage harmonic (THD) <2% <2% <2%
Switch time to emergency mode <10ms <10ms <20 ms
Rated output power 4000W / 4000VA 5000W / 5000VA 10000W / 10000VA
Peak output power 8400VA, 10s 8400VA, 10s 12000W / 12000VA, 5min
Downloads
Inst Manual Inst Manual Inst Manual
Data Sheet Data Sheet Data Sheet
EN Cert EN Cert  EN Cert
CE Declaration of Conformity CE Declaration of Conformity CE Declaration of Conformity

Relevant Sectors

Terrace.ie
Leinster Rugby
Gaiety Theatre
Dublin Airport
Clayton Hotel
Lloyds Pharmacy
Center Parcs
UCD
Google
WordPress Video Lightbox